Sign In | Join Free | My burrillandco.com
Home > Patient Monitor Accessories >

City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator from wholesalers
     
    Buy cheap City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator from wholesalers
    • Buy cheap City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator from wholesalers
    • Buy cheap City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator from wholesalers
    • Buy cheap City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator from wholesalers
    • Buy cheap City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator from wholesalers
    • Buy cheap City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator from wholesalers
    • Buy cheap City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator from wholesalers

    City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator

    Ask Lasest Price
    Brand Name : City
    Model Number : MOX3 MOX-3
    Payment Terms : T/T, Western Union,Paypal
    Delivery Time : 3-5 working days
    • Product Details
    • Company Profile

    City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator

    City MOX3 Medical Oxygen O2 Gas Sensor


    Specification of City MOX3 Medical Oxygen O2 Gas Sensor


    Product NameCity MOX3 Medical Oxygen O2 Gas Sensor
    BrandCity
    Model NumberMOX3 MOX-3
    Operating PrinciplePartial pressure electrochemical
    Output9 mV to 13 mV in 210 mBar O2
    Measurement Range0 mBar to 1500 mBar O2
    Temperature Compensation<2% O2 equivalent (0°C to 40°C)
    ConnectorUK Data Socket AMP (P/N 5520257-2)
    Housing MaterialWhite ABS
    Weight42 g
    Typical ApplicationsCritical care anesthesia
    Operating Temperature Range-20°C to +50°C
    Operating Pressure Range0.5 Bar to 2.0 Bar
    Operating Humidity Range0% to 99% RH noncondensing

    NOTE

    Specifications are based on cylinder gas measurements at 20 °C, 50% relative humidity, 1013 mBar and flow rate 100 ml/min-1 using the circuit recommended by City Technology. It represents the performance of the sensor during the first 3 months of service.


    Note : Using regression coefficients, the best fit straight line is better than 0.9995 when measured over 4 data points tested with 100% N2, 21% O2, 60% O2 and 100% O2.


    Intended Use

    City MOX3 Medical Oxygen O2 Gas sensors are designed to monitor oxygen pressure in anaesthesia (excluding xenon), intensive care, neonatal incubators and general oxygen monitors.


    Stabilization Time


    Allow at least 15 minutes for the equipment to stabilize before calibrating or refer to the manufacturer's instructions.


    Cleaning and Sterilization


    If the sensor becomes dirty, it should be cleaned with distilled water and allowed to air dry.


    Calibration Interval


    City MOX3 Medical Oxygen O2 Gas sensors are designed to have minimal drift throughout their life. If dropped, it should be isolated for 24 hours and checked using a two-point calibration.


    Mechanical Installation


    When installing the sensor, the sensor should be hand-tightened to ensure tightness. .


    Size of City MOX3 Medical Oxygen O2 Gas Sensor




    NOTE

    Connections should only be made using recommended coupling parts. Soldering the sensor will damage the sensor and void the warranty. For more information on connecting external load resistors and recommended coupling components, see OP-04 Principle of Operation or contact City Technology. All performance data is based on measurements with bottled gas using a flow rate of 100 mL/min. Conditions are 20 °C, 50 % relative humidity and 1013 mBar. Contact City Technology for sensor performance data under other conditions. Performance characteristics describe the performance of the sensor as supplied for the first three months. The output signal may drop below the lower limit over time.


    Thank you so much for your attention .If you're interested in City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 Ventilator ,feel free to contact us .Thank you .

    Quality City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: China World Technology Medical Equipment Service Group
    *Subject:
    *Message:
    Characters Remaining: (0/3000)