    Mindray Anesthetic Gas AG Module P/N 115-043908-00 For Hospital

    Ask Lasest Price
    Brand Name : Mindray
    Model Number : P/N 115-043908-00
    Certification : CE
    Payment Terms : In full before the shipment
    Delivery Time : 2-3 working days
    MOQ : One piece
    • Product Details
    • Company Profile

    Mindray Anesthetic Gas AG Module P/N 115-043908-00 For Hospital

    Mindray Anesthetic Gas (AG) Module P/N 115-043908-00 For Hospital

    The AG module analyzes gas samples from the patient and calculates CO2, O2, N2O, and AA waveforms and related numerics that include airway respiratory rate and MAC (minimum alveolar concentration).

    Measurement range:

    HAL, ENF, ISO, SEV, DES: 0~30 %,

    N2O: 0~100 %;

    awRR: 2~100 rpm

    Accuracy:

    Full accuracy mode: N2O: 0~20%REL: ±2% ABS, 20~100%REL: ±3%

    ABS; HAL,ENF,ISO: 0~1%REL: ±0.15% ABS, 1~5%REL: ±0.2% ABS, >5%REL, not specified; SEV: 0~1%REL: ±0.15% ABS, 1~5%REL: ±0.2% ABS, 5~8%REL: ±0.4% ABS, >8%REL, not specified;

    DES:0~1%REL: ±0.15% ABS, 1~5%REL: ±0.2% ABS, 5~10%REL: ±0.4% ABS, 10~15%REL: ±0.6% ABS ,15~18%REL: ±1% ABS ,>18%REL, not specified; awRR:2~60rpm, ±1rpm, >60rpm, not specified

    This measurement can be used for adults, pediatrics and neonates.

    Anesthetic Gas (AG) Module Alarm Messages

    MESSAGE CAUSE

    ALARM

    PRIORITY

    MACHINE

    MODE WHEN

    CHECKED

    DISABLE WHEN EXTERNAL AG

    IS IN STANDBY MODE

    AG Hardware Error

    AG module Hardware

    Error.

    Medium Runtime Yes
    O2 Sensor Error Paramagnetic O2 sensor error Medium Runtime Yes

    External AG Self

    Test Error

    Module fault or

    communication failure

    between the module and

    anesthesia system

    Low Runtime Yes

    AG Hardware

    Malfunction

    AG module hardware

    malfunction. The AG

    module enters Standby

    and measurement stops

    High Runtime Yes
    AG Init Error

    The AG module was

    installed improperly or

    malfunctioned.

    High Runtime Yes
    AG No Watertrap

    The AG module

    watertrap was installed

    improperly or not

    installed.

    Low Runtime Yes

    AG Watertrap Type

    Wrong

    When the patient type is

    infant, but the watertrap

    type is adult/pediatric,

    this alarm will be

    triggered

    Low Runtime Yes

    AG Change

    Watertrap

    When the actual flow is

    less than 75 % of the set

    flow, the alarm indicates

    that the watertrap is

    gradually occluded and it

    is necessary to replace

    the water trap

    Medium Runtime Yes
    AG Comm Stop

    AG module malfunction

    or communication

    failure.

    High Runtime No

    AG Airway

    Occluded

    Pump rate is lower than

    20 ml/min for 1 second.

    High Runtime Yes
    AG Zero Failed

    Gas measurements may

    have bad accuracy

    during zeroing

    Low Runtime Yes

    Mixed Agent and

    MAC < 3

    MAC < 3 Low Runtime Yes
    Mixed Agent and MAC ≥ 3 MAC ≥ 3 Medium Runtime Yes
    Mixed Agent

    Two anesthetic agents

    are detected but MAC is

    an invalid value.

    Medium Runtime Yes

    External AG

    Module

    Disconnected

    The external AG module

    has been disconnected

    and no O2 sensor is connected

    High Runtime Yes

    Incompatible AG

    Software Version

    The AG Version Limit is

    On, and the AG module is

    loaded while the AG

    software version is lower

    than 1.7.3.0

    High Runtime No

    CO2Over Range

    N 2 over Range Hal Over Range

    Enf Over Range

    Iso Over Range

    Sev Over Range

    Des Over Range

    O2 Over Range

    Rate Over Range

    The monitoring value

    exceeds the measurable range

    Low Runtime Yes

    Mindray Anesthetic Gas AG Module P/N 115-043908-00 For Hospital

    Quality Mindray Anesthetic Gas AG Module P/N 115-043908-00 For Hospital for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: China World Technology Medical Equipment Service Group
    *Subject:
    *Message:
    Characters Remaining: (0/3000)