| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | PHiliph |
| Model Number : | M4572B |
| Certification : | CE |
| Payment Terms : | T/T, Western Union,Paypal |
M4572B PHiliphhilip Neonatal newborn NIBP cuff Gentle Care Infant
Product Description:
Product features
Strength and reliability of products
Our gentle care cuff is designed to meet the needs of hospitals and
nurses. These cuff samples passed the pipe connection durability
test, hook and loop durability test, joint durability test and
burst resistance test.
The product is suitable for diversified nursing environment
The single patient cuff of gentle care has an integrated bladder,
which is very suitable for operating room, emergency room, catheter
room and isolation room. Or other use that requires NBP cuff for
single patient.
The product has high comfort and small use area.
The purpose of the soft felt cover on the cuff is to improve the
baby's comfort.
Product visual recognition
Gentle care cuffs are color coded and externally dimensioned for
visual recognition.
Newborns are a very vulnerable population and have very high requirements for medical equipment, including monitoring equipment and consumables. Therefore, choosing a big brand is the first choice for many large hospitals.
PHiliphhilip is a medical equipment manufacturer with a history of more than 100 years and is very experienced in the care of newborns.
Use with PHiliphhilip Healthcare Equipment as follows:
M1008A, M1008B, M1176A, M3000A, M3001A, M3002A, 862474, 862478,
863055, 863057, 863058, 863059, 863060, 863061, 863062, 863063,
863064, 863065, 863066, 863068, 863069, 863070, 863071, 863072,
863073, 863074, 863079, 863080, 863081, 863082, MP5, M8105A,
M8105AT, M8102A, 863086, 863087, 863088, 863275, 863276, 863278,
M3535A, M3536A, M3536M, M8105AS
How to use a newborn cuff
Are you still worried about how to choose newborn cuff. The parents
of many newborns may be exposed to this blood pressure cuff for the
first time. They know so little about such a medical device that
they are in a very confused space.
Selection and size of neonatal blood pressure cuff:
1. The width is 9cm, the length is 18cm, and the maximum upper arm
circumference is 22cm
2. The width is 4cm, the length is 8cm, and the maximum
circumference of the upper arm is 10cm
3. The width is 6cm, the length is 12cm, and the maximum
circumference of the upper arm is 15cm
Position of neonatal cuff measurement:
The correct position for neonatal blood pressure measurement is 2 ~
3cm from the lower edge of the cuff to the transverse line of the
cubital fossa. If you don't do this, it may affect the accuracy of
blood pressure measurement. When we buy, we must read the manual
carefully. If we don't understand it very well, we suggest you
consult the doctor of the nearest hospital.
Measurement skills of neonatal cuff:
1. Open the sPHiliphhilipygmomanometer box, place it in a stable
place near the newborn's limbs, and make the mercury column
vertical to zero.
2. Keep quiet indoors and avoid newborn crying before measurement.
3. When wrapping the sPHiliphhilipygmomanometer air sleeve, first
squeeze out the air in the air sleeve, and then wrap it 2 ~ 3cm
above the elbow joint of the right upper arm. It should not be too
loose or too tight. After touching the beating of the brachial
artery on the inner side of the time fossa, put the stethoscope
head on the brachial artery and pump air for pressure measurement.
4. Close the valve on the balloon, and the surveyor's line of sight
should be at the same level as the scale on the mercury column to
observe the height of the mercury column. Inflate rapidly. When the
radial artery pulse disappears, pressurize 4kPa (30mmhg) to stop
inflation. Slightly open the air valve to make the mercury slowly
drop. When the first sound of pulse beating is heard, it is "high
pressure", that is, systolic blood pressure. Continue to deflate
slightly, and the mercury slowly drops to a certain scale on the
mercury column. When the sound suddenly weakens or disappears, it
is "low pressure", that is, diastolic blood pressure.
5. The newborn lies flat with his feet flat, and his elbows and
forearms are comfortably placed in a position approximately
parallel to the heart. Take off the sleeve to expose the right
upper arm. If the sleeve is thin and wide, it can be rolled up to
the armpit.
6. After the first measurement, completely deflate, wait for at
least one minute, and then repeat the measurement again. Take the
average value of the two times as the obtained blood pressure
value. The systolic blood pressure of newborns was 6.7 ~ 8.8 Okpa
(50 ~ 60mmfig), diastolic pressure 4 ~ 5.3kpa (30 ~ 40mmh9).
►FAQ
| Q1 | How can I pay for it? |
| A1 | T/T,Western Union, PayPal are all acceptable. |
| Q2 | What are your main brands? |
| A2 | PHiliphhilip, Mindray, GE, NIHON KOHDEN, Goldway, etc. |
| Q3 | How long will it take to receive the goods? |
| A3 | It depends on your shipping address. |
| Q4 | What will you do if you find any quality problems within the warranty period? |
| A4 | Repair or replace according to the actual situation. |
|