Sign In | Join Free | My burrillandco.com
Home > Defibrillator Machine Parts >

Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022638A-S UR-0249

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022638A-S UR-0249 from wholesalers
     
    Buy cheap Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022638A-S UR-0249 from wholesalers
    • Buy cheap Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022638A-S UR-0249 from wholesalers
    • Buy cheap Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022638A-S UR-0249 from wholesalers
    • Buy cheap Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022638A-S UR-0249 from wholesalers
    • Buy cheap Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022638A-S UR-0249 from wholesalers

    Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022638A-S UR-0249

    Ask Lasest Price
    Brand Name : Nihon Kohden
    Model Number : TEC-7621C
    Payment Terms : T/T, Western Union,PayPal
    Delivery Time : 3-5 working days
    • Product Details
    • Company Profile

    Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022638A-S UR-0249


    Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022647-S


    ►Brief Introduction


    ► How to use

    Power On: Ensure that the defibrillator is powered on and ready for use. This may involve connecting the device to a power source or ensuring that the battery is adequately charged.

    Check Settings: Before using the keypad board, verify that the defibrillator is set to the appropriate mode for the intended procedure (e.g., cardioversion, defibrillation) and that the energy levels are correctly configured based on the patient's condition.

    User Interface: The keypad board typically consists of buttons, indicators, and possibly a display screen. Familiarize yourself with the layout of the keypad and understand the functions of each button.

    Input Commands: Use the keypad board to input commands such as selecting energy levels, adjusting settings, activating monitoring functions, and navigating through menu options. Follow on-screen prompts and visual indicators for guidance.

    Energy Delivery: When delivering a shock, follow the specific procedure recommended by the manufacturer. This may involve charging the defibrillator to the appropriate energy level, ensuring proper electrode placement on the patient's chest, and delivering the shock when prompted.

    Monitoring and Feedback: Use the keypad board to monitor patient status, review recorded data, and receive feedback from the defibrillator regarding the effectiveness of interventions.


    ► Specification

    Operating temperature0 to 45°C (32 to 113°F)
    Operating humidity:0 to 40°C: 30 to 95% (relative humidity, non-condensing)
    40 to 45°C: 30 to 80% (relative humidity, non-condensing)
    Operating atmospheric pressure:70 to 106 kPa
    Storage temperature:-20 to 70°C (-4 to 158°F)
    Storage humidity:10 to 95% (relative humidity, non-condensing)
    Storage atmospheric pressure:50 to 106 kPa

    ► Overview

    1. Record key

    2. Recording lamp

    3. Event key

    4. Event lamp

    5. ECG lead key

    6. ECG sensitivity key

    7. SILENCE ALARM key

    8. Alarm setting key

    9. AC lamp

    10. Battery charging lamp

    11. Battery charge complete lamp


    ► Removing the Main Key Board and Key Board

    1. Remove the battery pack, memory card and lower casing.

    2 Remove the main chassis and main board.

    3. Disconnect the following cables:

    • Rotary switch cable.
    • CNA201 cable: Connects to the test load.
    • CNA102 film cable: Connects to the main key board and key board.

    To remove the film cable from the film cable connector, gently release the lock of the film cable connector with a small flat blade driver and your finger as shown in the expanded illustration. Be careful because the film cable connector is easily damaged.

    4. Remove the three M3 pan screws with washers and spring washers and remove the main key board.

    5. Remove the two M3 pan screws with washers and spring washers and remove the key board.

    To remove the Energy/Mode Select control knob on the front panel.

    1) Remove the two allen screws on the Energy/Mode Select control knob.

    2) Remove the knob, nut, washer and O ring from the rotary switch


    Thank you for your time! If you want to explore more details about Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022647-S, please let us know. Customer satisfaction. Our biggest pursuit!

    Quality Nihon Kohden Cardiolife TEC-7621C Defibrillator Keypad Board 6190-022638A-S UR-0249 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: China World Technology Medical Equipment Service Group
    *Subject:
    *Message:
    Characters Remaining: (0/3000)