Sign In | Join Free | My burrillandco.com
Home > ECG Machine Parts >

AAMI REF 989803129231 Alligator Clips AAMI Bag Of 10 1/8" Post For Tab Electrodes

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap AAMI REF 989803129231 Alligator Clips AAMI Bag Of 10 1/8" Post For Tab Electrodes from wholesalers
     
    Buy cheap AAMI REF 989803129231 Alligator Clips AAMI Bag Of 10 1/8" Post For Tab Electrodes from wholesalers
    • Buy cheap AAMI REF 989803129231 Alligator Clips AAMI Bag Of 10 1/8" Post For Tab Electrodes from wholesalers
    • Buy cheap AAMI REF 989803129231 Alligator Clips AAMI Bag Of 10 1/8" Post For Tab Electrodes from wholesalers
    • Buy cheap AAMI REF 989803129231 Alligator Clips AAMI Bag Of 10 1/8" Post For Tab Electrodes from wholesalers
    • Buy cheap AAMI REF 989803129231 Alligator Clips AAMI Bag Of 10 1/8" Post For Tab Electrodes from wholesalers

    AAMI REF 989803129231 Alligator Clips AAMI Bag Of 10 1/8" Post For Tab Electrodes

    Ask Lasest Price
    Brand Name : PHiliph
    Model Number : 989803129231
    Payment Terms : T/T, Western Union,PayPal
    Delivery Time : 3-5 working days
    • Product Details
    • Company Profile

    AAMI REF 989803129231 Alligator Clips AAMI Bag Of 10 1/8" Post For Tab Electrodes


    PHiliphh Alligator Clips,AAMI REF 989803129231 Alligator Clips AAMI (Bag of 10) 1/8" post., for tab electrodes


    ► Brief Introduction

    Acquisition of quality ECG data is critical in providing accurate and timely diagnosis and patient treatment. Poor ECG quality can:

    • result in the monitor’s inability to recognize the R-wave, thus affecting arrhythmia analysis and the ability to perform procedures such as synchronized cardioversion and transcutaneous pacing,
    • inhibit reading a 12-Lead accurately, and
    • result in false alarms and unnecessary troubleshooting, potentially delaying treatme

    ► Lead Selection

    It is important to select a suitable lead that shows the largest amplitude and cleanest signal so that a QRS complex and R-wave, in particular, can be accurately detected by the monitor. Consider the following lead selection guidelines:

    • The QRS complex should be tall and narrow (recommended amplitude > 0.5 mV).
    • The R-wave should be above or below the baseline (but not biphasic).
    • The P-wave should be smaller than (1/5) R-wave height.
    • The T-wave should be smaller than (1/3) R-wave height.

    To prevent detection of P-waves or baseline noises as QRS complexes, the minimum detection level for QRS complexes is set at 0.15 mV, according to AAMI-EC 13 specifications. If the ECG signal is too weak, you may get false alarms for asystole.In many monitors, increasing the gain (size) of the ECG does not change the signal to the monitor. Therefore, the signal should meet the above criteria without changing the gain to ensure the monitor can accurately analyze the waveform.


    ► Specifications


    Product CategoryECG
    Use with Non-PHiliphh Healthcare EquipmentNo
    Single-Patient Use OR Multi-Patient UseMulti-Patient Use
    Not manufactured with natural rubber latexYes
    Packaging Unit10 adapters
    Minimum Shelf LifeNone
    Sterile OR Non-SterileNon-Sterile
    Use with PHiliphh Healthcare Equipment860284, 860286, 860287, 860288, 860290, 860297, 860284, 860300, 860310, 860315

    ► About Us

    CWT Technology HK Limited, located in Guangzhou, China. During these years of marketing and expansion, we have accumulated a great wealth of experience in both product distribution and customer service. We are a trustworthy medical equipment supplier where we have been involved in the industry for many years. The customer will receive satisfactory goods.
    I have supply the medical equipment and parts of Patient Monitor, Defibrillator Machine, ECG Machine,Ultrasound such as
    GE,
    PHiliphhilip,
    Mindray,
    Goldway,
    Nihon Kohden,
    Med-tronic,
    Drager,
    Edan,
    Zoll,
    etc.,
    We understand the importance of the concept of win-win cooperation, are committed to protecting the medical equipment market, and meeting all customer requests is our constant pursuit.


    Thank you for your time! If you are interested in PHiliphh Alligator Clips,AAMI REF 989803129231 Alligator Clips AAMI (Bag of 10) 1/8" post., for tab electrodes , welcome to place your orders. Early order early shipment! Looking forward to receiving your early inquiry.

    Quality AAMI REF 989803129231 Alligator Clips AAMI Bag Of 10 1/8" Post For Tab Electrodes for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: China World Technology Medical Equipment Service Group
    *Subject:
    *Message:
    Characters Remaining: (0/3000)