Sign In | Join Free | My burrillandco.com
Home > Patient Monitor Parts >

Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121 from wholesalers
     
    Buy cheap Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121 from wholesalers
    • Buy cheap Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121 from wholesalers
    • Buy cheap Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121 from wholesalers
    • Buy cheap Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121 from wholesalers
    • Buy cheap Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121 from wholesalers
    • Buy cheap Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121 from wholesalers
    • Buy cheap Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121 from wholesalers

    Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121

    Ask Lasest Price
    Brand Name : Mindray
    Model Number : 630D-30-09122 630D-30-09121
    Payment Terms : T/T(wire transfer), Western Union, Paypal
    Delivery Time : 3-5 working days
    • Product Details
    • Company Profile

    Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121

    630D-30-09122 630D-30-09121 Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump


    NIBP module introduction

    The Non-Invasive Blood Pressure (NIBP) module measures blood pressure using oscillometric methods. This monitor can be used for adult, pediatric and neonatal patients.

    There are three measurement modes: manual, automatic, and continuous.


    Manual: Press the NIBP button on the control panel to start NIBP measurement.

    Automatic: Automatically performs NIBP measurements at preset intervals.

    Continuous: NIBP measurements are taken as many times as possible within 5 minutes.


    NIBP measurements do not generate waveforms. Instead, the measurements are displayed in the NIBP Parameters window as shown below.



    1. NIBP Tab: Select this tab to access the NIBP setup menu.

    2. The time of the last measurement.

    3. NIBP unit: mmHg or kPa.

    4. Quick Information Area: Displays information such as NIBP measurement mode.

    5. Systolic blood pressure (SBP)

    6. Average pressure value (NM)

    7. Diastolic blood pressure (DN)


    Specification of NIBP

    Measurement techniqueAuto oscillation
    Displayed parametersSystolic pressure, diastolic pressure and mean pressure
    Mode of operationManual, auto and continuous
    Measurement interval in auto mode1/2/3/4/5/10/15/30/60/90/120/180/240/480 minutes
    Measurement time in continuous mode5 minutes
    Measurement precisionMaximum average error: ±5mmHg Maximum standard deviation: 8mmHg
    Resolution1mmHg
    Over-pressure protection

    Adult: 297±3 mmHg

    Pediatric: 240±3 mmHg

    Neonate: 147±3 mmHg


    Operation Guides


    1. Start a manual NIBP measurement

    Go to the NIBP SETUP menu and select MANUAL from the INTERVAL option; Then press the NIBP button on the control panel to start manual NIBP measurement; either

    To start a manual NIBP measurement between automatic NIBP measurements, press the NIBP button on the control panel.


    2. Start the automatic NIBP measurement Go to the NIBP SETUP menu and select a time (e.g. 5 MIN) from the INTERVAL option. Start the automatic NIBP measurement by pressing the NIBP button on the control panel. When the measurement is complete, the system automatically performs a non-invasive blood pressure measurement according to the preset interval.


    Warning

    Long-term use of automated, non-invasive blood pressure measurements can lead to ischemia and neuropathy in the restricted limb. When observing patients, regularly check the color, temperature and sensation of the extremities. If you notice abnormalities, immediately put the cuff back on the patient or stop the blood pressure measurement.


    3. Start continuous NIBP measurement. Select NEXT from the NIBP SETUP menu to start a continuous NIBP measurement. The monitor will continue to measure NIBP for five minutes.

    4. Stop NIBP measurement During automatic, manual or continuous measurement, press the NIBP button on the control panel to stop the current measurement.



    Thank you so much for your attention .If you're interested in 630D-30-09122 630D-30-09121 Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump ,feel free to contact us .Thank you .


    Quality Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump 630D-30-09122 630D-30-09121 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: China World Technology Medical Equipment Service Group
    *Subject:
    *Message:
    Characters Remaining: (0/3000)